Error message | Description | What to do ?? | Remark |
Er0 | Over-torque of 110% of max. torque spec.
If a wrench is overloaded, the LCD screen will report it by showing “Er0” when power on the unit.
***Overload = 110% of maximum torque***
e.g. Model SP35357, Max. torque is 200Nm, above 220Nm means overload. | Contact local dealer | What dealer should do: Step 1: Check if the accuracy is out of range. Step 2: - If still within the guaranteed range: use Er0 remover software to remove the “Er0” from the display. - If out of guaranteed range: re-calibrate, then, use Er0 remover software to remove the “Er0” from the display.
|
Er1~Er3 | Original factory test when manufacturing | - - - - - - - - - - - - - - - | Users can’t see these Er. |
Er4 | 1) Angle module initialization (。。。。) too long 2) Wrench not in rest status: the angle sensor feeling a movement which causes sensor keeping counting angle, so the wrench cannot be reset and start working. 3) Applying a tightening too fast. (solution: please slow down a bit to avoid problem occur) | Press C to re-start the unit.
The unit must be held still during angle initialization | Wrench must be placed flat (horizontally) on table or workbench before any attempt is made to change values or to power up the unit.
Press C to re-start the unit.
|
Er5 | Angle module communication fail | Press C to re-start the unit. | It means PC Board problem, press C to re-start the unit. If fail, contact local dealer. Dealer should change the screen panel. |
Er-- | Rotation speed too fast in angle mode | Rotate wrench within 30°/sec in angle mode | Press C to re-start the unit. |
Models: SP35155, SP35255, SP35355, SP35356 - SP352556, SP35357, SP35358